  • Relay Test Set

    Cambridge Instruments & Engineering Co.

    “CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.

  • Relay Test Set

    R.R.Transformers & Equipments

    Relay testing equipment is a portable apparatus designed for checking the operating characteristics of protective relays on site. Rr Relay Testing Equipments are designed to facilitate routine test or periodic maintenance test of relays by simulating (as early as possible) fault conditions under which the protective relays are required to function. There are several approaches to the method of testing relays on site. The Relay Testing Equipments are secondary injection type and are intended to be used to test the relays after isolating them from live systems, either physically or electrically.

  • Secondary Injection Equipment for Relay Testing

    EUROSMC, S.A.

    Portable equipment to test all types of protective relays and power system protection schemes. Automatic relay testing software, Comtrade transient playback and test reporting.

  • Secondary Injection Relay Test Set

    T 1000 PLUS - Altanova Group

    T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment.

  • Power System Simulator

    F6150e - Manta Test Systems

    This power system simulator performs the simplest through the most complex tests. Meeting all your protective relay testing needs, the F6150e is available in different configurations.

  • Secondary Injection Relay Test Set

    TD 1000 PLUS - Altanova Group

    TD1000+ is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. In comparison with T 1000 PLUS model, TD 1000 PLUS has two current outputs to test the differential relay characteristic curve, besides the pick-up current.

  • THREE PHASE SECONDARY CURRENT INJECTION TEST SET

    TEST-330B - Beijing GFUVE Electronics Co.,Ltd.

    Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.

  • Primary Current Injection

    PCI-600 - Manta Test Systems

    The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers.

  • Primary Current Injection Testers

    Hilkar

    Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.

  • Digital Test Switch

    FT-14D - ABB Ltd.

    Test switch solution for digital switchgear using current and voltage sensors. With the FT-14D Digital FlexitestTM switches, a new era of protection relay testing can be performed more safely, quickly and easily. The FT-14D switch allows a customer to integrate current and voltage sensors within digital switchgear and protective relays and thereby enable the Industrial Internet of Things.

  • Relay Test Equipment

    Vanguard Instruments Company, Inc.

    The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.

  • Transformer Demagnetization Tester

    Weshine Electric Manufacturing Co., Ltd

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Step Up Transformer

    MagD - Scope T&M Pvt, Ltd.

    SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.